Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Clin Spine Surg ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637933

RESUMO

STUDY DESIGN: Single-center retrospective study. OBJECTIVE: The objective of this study is to identify the factors leading to repeat surgery in patients with cervical ossification of the longitudinal ligament (OPLL) during a minimal 8-year follow-up after the initial surgery. SUMMARY OF BACKGROUND DATA: The long-term effects of cervical OPLL are well known, but it's not always clear how many patients need to have surgery again because their neurological symptoms get worse. METHODS: This study is included 117 patients who underwent surgery for cervical OPLL and had a follow-up of at least 8 years. OPLL type, surgical extent, surgical method, and sagittal radiological parameters were measured, and OPLL characteristics were analyzed. RESULTS: The average age of patients at the time of surgery was 53.2 years, with a male-to-female ratio of 78:39. The median follow-up duration was 122 months (96-170 mo). Out of the total, 20 cases (17.1%) necessitated repeat surgery, among which 8 cases required surgery at the same site as the initial operation. The highest rate of repeat surgery was observed in patients who underwent total laminectomy without fusion (TL), where 6 out of 21 patients (29%) needed a second surgery, and 5 of these (23%) involved the same surgical site. Patients who underwent repeat surgery at the same site exhibited a greater range of motion (ROM) one year postsurgery (16.4 ± 8.5° vs. 23.1 ± 12.7°, P=0.041). In addition, the ROM at 1 year was higher in patients who underwent TL compared with those who had laminoplasty. Furthermore, the recurrence rate for hill-shape OPLL was higher at 30.8% compared to 10% for plateau-shape OPLL (P = 0.05). CONCLUSION: Larger cervical ROM 1 year after surgery is related to repeat surgery at the same level as previous surgery, especially in laminectomy without fusion surgery.

2.
Neurospine ; 21(1): 83-94, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38569633

RESUMO

OBJECTIVE: This study aimed to compare the accuracy of robotic spine surgery and conventional pedicle screw fixation in lumbar degenerative disease. We evaluated clinical and radiological outcomes to demonstrate the noninferiority of robotic surgery. METHODS: This study employed propensity score matching and included 3 groups: robot-assisted mini-open posterior lumbar interbody fusion (PLIF) (robotic surgery, RS), c-arm guided minimally invasive surgery transforaminal lumbar interbody fusion (C-arm guidance, CG), and freehand open PLIF (free of guidance, FG) (54 patients each). The mean follow-up period was 2.2 years. The preoperative spine condition was considered. Accuracy was evaluated using the Gertzbein-Robbins scale (GRS score) and Babu classification (Babu score). Radiological outcomes included adjacent segmental disease (ASD) and mechanical failure. Clinical outcomes were assessed based on the visual analogue scale, Oswestry Disability Index, 36-item Short Form health survey, and clinical ASD rate. RESULTS: Accuracy was higher in the RS group (p < 0.01) than in other groups. The GRS score was lower in the CG group, whereas the Babu score was lower in the FG group compared with the RS group. No significant differences were observed in radiological and clinical outcomes among the 3 groups. Regression analysis identified preoperative facet degeneration, GRS and Babu scores as significant variables for radiological and clinical ASD. Mechanical failure was influenced by the GRS score and patients' age. CONCLUSION: This study showed the superior accuracy of robotic spine surgery compared with conventional techniques. When combined with minimally invasive surgery, robotic surgery is advantageous with reduced ligament and muscle damage associated with traditional open procedures.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38650430

RESUMO

Objective: Spinal intramedullary hemangioblastoma is a rare and highly vascularized benign tumor. The characteristics of the tumor, its corresponding location, and surgical outcomes remain unknown. The purpose of this study was to identify risk factors and strategies for neurologic deterioration following hemangioblastoma surgery. Methods: A comprehensive retrospective analysis was undertaken to evaluate patients who underwent surgical intervention for intramedullary hemangioblastoma at our institution from 1993 to 2022. Patients with at least one year of follow-up data were included. The analysis covered patient demographics, pre- and post-operative Modified McCormick Scale (MMCS), tumor location, and tumor size. Results: This study included 25 cases. One-year after surgery, neurological deterioration was observed in 5 (20.0%) cases, and neurological improvement was found in 9 (36.0%) cases. Five cases were ventrally located, and twelve cases were dorsally located. Ventrally located cases were larger in tumor axial size (p = 0.029) than dorsal location tumors, resulting in poorer follow-up MMCS and a higher prevalence of von Hippel-Lindau syndrome (VHL) (p = 0.042). Three of them were confirmed to be supplied by the anterior spinal artery. In the case of dorsally located cases, there was no neurologic deterioration. Conclusion: In intramedullary spinal cord hemangioblastomas, cases located ventrally had a higher incidence of neurological deterioration following surgery than those located dorsally or in intramedullary extramedullary cases. Ventrally located hemangioblastomas were larger than those in other locations. They were mainly supplied by the anterior spinal artery in VHL patients.

4.
Exp Mol Med ; 55(10): 2190-2204, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37779150

RESUMO

Recent developments in tissue clearing methods such as the passive clearing technique (PACT) have allowed three-dimensional analysis of biological structures in whole, intact tissues, thereby providing a greater understanding of spatial relationships and biological circuits. Nonetheless, the issues that remain in maintaining structural integrity and preventing tissue expansion/shrinkage with rapid clearing still inhibit the wide application of these techniques in hard bone tissues, such as femurs and tibias. Here, we present an optimized PACT-based bone-clearing method, Bone-mPACT+, that protects biological structures. Bone-mPACT+ and four different decalcifying procedures were tested for their ability to improve bone tissue clearing efficiency without sacrificing optical transparency; they rendered nearly all types of bone tissues transparent. Both mouse and rat bones were nearly transparent after the clearing process. We also present a further modification, the Bone-mPACT+ Advance protocol, which is specifically optimized for processing the largest and hardest rat bones for easy clearing and imaging using established tissue clearing methods.


Assuntos
Osso e Ossos , Imageamento Tridimensional , Ratos , Camundongos , Animais , Imageamento Tridimensional/métodos , Osso e Ossos/diagnóstico por imagem
5.
World Neurosurg ; 179: 127-132, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37619844

RESUMO

In endoscopic thoracic spine surgery, adaptations of thoracic surgical techniques such as full endoscopic uniportal and biportal surgical techniques have been developed. Full endoscopic uniportal surgery for thoracic disc herniation or thoracic ossified ligamentum flavum (OLF) has been performed via transforaminal and interlaminar approaches. In the case of thoracic OLF or thoracic spinal stenosis, the uniportal interlaminar approach is appropriate. The uniportal interlaminar approach has been used to treat thoracic OLF and has shown good surgical results. Thoracic OLF removal via a biportal endoscopic technique has been developed recently and is described in a few studies. Although endoscopic thoracic spine surgery has significant advantages, complications often occur with this approach. We reviewed the literature to date on the complications associated with endoscopic spine surgery in thoracic pathology. This review emphasizes how to avoid and manage complications. Based on the results of several previous studies, endoscopic thoracic spine surgery could be associated with fewer potential complications than conventional surgery. Endoscopic spine surgery has remarkable advantages; however, endoscopic thoracic surgery is technically challenging and is potentially associated with serious complications. To minimize the risk of avoidable complications, surgeons should be familiar with prevention methods and pitfalls.


Assuntos
Descompressão Cirúrgica , Ligamento Amarelo , Humanos , Descompressão Cirúrgica/métodos , Resultado do Tratamento , Estudos Retrospectivos , Endoscopia/efeitos adversos , Endoscopia/métodos , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Ligamento Amarelo/cirurgia
6.
Br J Cancer ; 129(7): 1061-1070, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37558923

RESUMO

BACKGROUND: Glioblastoma (GBM), one of the most lethal tumors, exhibits a highly infiltrative phenotype. Here, we identified transcription factors (TFs) that collectively modulate invasion-related genes in GBM. METHODS: The invasiveness of tumorspheres (TSs) were quantified using collagen-based 3D invasion assays. TF activities were quantified by enrichment analysis using GBM transcriptome, and confirmed by cell-magnified analysis of proteome imaging. Invasion-associated TFs were knocked down using siRNA or shRNA, and TSs were orthotopically implanted into mice. RESULTS: After classifying 23 patient-derived GBM TSs into low- and high-invasion groups, we identified active TFs in each group-PCBP1 for low invasion, and STAT3 and SRF for high invasion. Knockdown of these TFs reversed the phenotype and invasion-associated-marker expression of GBM TSs. Notably, MRI revealed consistent patterns of invasiveness between TSs and the originating tumors, with an association between high invasiveness and poor prognosis. Compared to controls, mice implanted with STAT3- or SRF-downregulated GBM TSs showed reduced normal tissue infiltration and tumor growth, and prolonged survival, indicating a therapeutic response. CONCLUSIONS: Our integrative transcriptome analysis revealed three invasion-associated TFs in GBM. Based on the relationship among the transcriptional program, invasive phenotype, and prognosis, we suggest these TFs as potential targets for GBM therapy.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Animais , Humanos , Camundongos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/tratamento farmacológico , Linhagem Celular Tumoral , Proliferação de Células , Perfilação da Expressão Gênica , Glioblastoma/diagnóstico por imagem , Glioblastoma/genética , Glioblastoma/tratamento farmacológico , Invasividade Neoplásica/patologia , Prognóstico , RNA Interferente Pequeno , Isocitrato Desidrogenase/genética , Isocitrato Desidrogenase/metabolismo , Fator de Transcrição STAT3/genética , Fator de Transcrição STAT3/metabolismo
7.
J Pers Med ; 13(5)2023 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-37240880

RESUMO

Pain generator-based lumbar spinal decompression surgery is the backbone of modern spine care. In contrast to traditional image-based medical necessity criteria for spinal surgery, assessing the severity of neural element encroachment, instability, and deformity, staged management of common painful degenerative lumbar spine conditions is likely to be more durable and cost-effective. Targeting validated pain generators can be accomplished with simplified decompression procedures associated with lower perioperative complications and long-term revision rates. In this perspective article, the authors summarize the current concepts of successful management of spinal stenosis patients with modern transforaminal endoscopic and translaminar minimally invasive spinal surgery techniques. They represent the consensus statements of 14 international surgeon societies, who have worked in collaborative teams in an open peer-review model based on a systematic review of the existing literature and grading the strength of its clinical evidence. The authors found that personalized clinical care protocols for lumbar spinal stenosis rooted in validated pain generators can successfully treat most patients with sciatica-type back and leg pain including those who fail to meet traditional image-based medical necessity criteria for surgery since nearly half of the surgically treated pain generators are not shown on the preoperative MRI scan. Common pain generators in the lumbar spine include (a) an inflamed disc, (b) an inflamed nerve, (c) a hypervascular scar, (d) a hypertrophied superior articular process (SAP) and ligamentum flavum, (e) a tender capsule, (f) an impacting facet margin, (g) a superior foraminal facet osteophyte and cyst, (h) a superior foraminal ligament impingement, (i) a hidden shoulder osteophyte. The position of the key opinion authors of the perspective article is that further clinical research will continue to validate pain generator-based treatment protocols for lumbar spinal stenosis. The endoscopic technology platform enables spine surgeons to directly visualize pain generators, forming the basis for more simplified targeted surgical pain management therapies. Limitations of this care model are dictated by appropriate patient selection and mastering the learning curve of modern MIS procedures. Decompensated deformity and instability will likely continue to be treated with open corrective surgery. Vertically integrated outpatient spine care programs are the most suitable setting for executing such pain generator-focused programs.

8.
Neurospine ; 20(1): 43-55, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37016853

RESUMO

Many types of surgeries are changing from conventional to minimally invasive techniques. Techniques in spine surgery have also changed, with endoscopic spine surgery (ESS) becoming a major surgical technique. Although ESS has advantages such as less soft tissue dissection and normal structure damage, reduced blood loss, less epidural scarring, reduced hospital stay, and earlier functional recovery, it is not possible to replace all spine surgery techniques with ESS. ESS was first used for discectomy in the lumbar spine, but the range of ESS has expanded to cover the entire spine, including the cervical and thoracic spine. With improvements in ESS instruments (optics, endoscope, endoscopic drill and shaver, irrigation pump, and multiportal endoscopic), limitations of ESS have gradually decreased, and it is possible to apply ESS to more spine pathologies. ESS currently incorporates new technologies, such as navigation, augmented and virtual reality, robotics, and 3-dimentional and ultraresolution visualization, to innovate and improve outcomes. In this article, we review the history and current status of ESS, and discuss future goals and possibilities for ESS through comparisons with conventional surgical techniques.

9.
Neurospine ; 20(1): 265-274, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37016873

RESUMO

OBJECTIVE: This study aimed to create an ideal machine learning model to predict mechanical complications in adult spinal deformity (ASD) surgery based on GAPB (modified global alignment and proportion scoring with body mass index and bone mineral density) factors. METHODS: Between January 2009 and December 2018, 238 consecutive patients with ASD, who received at least 4-level fusions and were followed-up for ≥ 2 years, were included in the study. The data were stratified into training (n = 167, 70%) and test (n = 71, 30%) sets and input to machine learning algorithms, including logistic regression, random forest gradient boosting system, and deep neural network. RESULTS: Body mass index, bone mineral density, the relative pelvic version score, the relative lumbar lordosis score, and the relative sagittal alignment score of the global alignment and proportion score were significantly different in the training and test sets (p < 0.05) between the complication and no complication groups. In the training set, the area under receiver operating characteristics (AUROCs) for logistic regression, gradient boosting, random forest, and deep neural network were 0.871 (0.817-0.925), 0.942 (0.911-0.974), 1.000 (1.000-1.000), and 0.947 (0.915-0.980), respectively, and the accuracies were 0.784 (0.722-0.847), 0.868 (0.817-0.920), 1.000 (1.000-1.000), and 0.856 (0.803-0.909), respectively. In the test set, the AUROCs were 0.785 (0.678-0.893), 0.808 (0.702-0.914), 0.810 (0.710-0.910), and 0.730 (0.610-0.850), respectively, and the accuracies were 0.732 (0.629-0.835), 0.718 (0.614-0.823), 0.732 (0.629-0.835), and 0.620 (0.507-0.733), respectively. The random forest achieved the best predictive performance on the training and test dataset. CONCLUSION: This study created a comprehensive model to predict mechanical complications after ASD surgery. The best prediction accuracy was 73.2% for predicting mechanical complications after ASD surgery.

10.
Korean J Ophthalmol ; 37(3): 245-254, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37068832

RESUMO

PURPOSE: A systematic review of the literature on diagnostic and therapeutic indications, techniques, and complications of dacryoendoscopy (DE) was performed. METHODS: The authors performed a PubMed search of articles published in English on DE. Data were collected and classified according to the categories of the disease. The clinical outcomes and limitations were particularly analyzed. RESULTS: The lacrimal drainage system from the canaliculus to the inferior meatus could be examined based on the specific anatomical features by DE. The canalicular mucosa is smooth and brightly colored, the lacrimal sac shows covering mucosa with good vascularization and the nasolacrimal duct is lined with bright tubular mucosal folds. DE allows direct visualization of the detailed internal condition of the lacrimal disorders, to directly diagnose the site of obstruction with accuracy and address the causes and recanalize the lacrimal drainage system using assisted micro lacrimal surgical instruments in the tearing patients. CONCLUSIONS: Better visualization of the lacrimal canal with DE improves the understanding of physiology and precise identification of the obstructing lesions, both of which are the key to a comprehensive management for the tearing patients.


Assuntos
Dacriocistorinostomia , Lacerações , Doenças do Aparelho Lacrimal , Aparelho Lacrimal , Obstrução dos Ductos Lacrimais , Ducto Nasolacrimal , Humanos , Dacriocistorinostomia/métodos , Doenças do Aparelho Lacrimal/cirurgia , Ducto Nasolacrimal/cirurgia , Lágrimas , Lacerações/cirurgia , Obstrução dos Ductos Lacrimais/diagnóstico
11.
J Neurosurg Spine ; 38(2): 165-173, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36152325

RESUMO

OBJECTIVE: Mechanical complications should be considered following the correction of multilevel posterior cervical instrumented fusion. This study aimed to investigate clinical data on the patients' pre- and postoperative cervical alignment in terms of the incidence of mechanical complications after multilevel posterior cervical instrumented fusion. METHODS: Between January 2008 and December 2018, 156 consecutive patients who underwent posterior cervical laminectomy and instrumented fusion surgery of 4 or more levels and were followed up for more than 2 years were included in this study. Age, sex, bone mineral density (BMD), BMI, mechanical complications, and pre- and postoperative radiographic factors were analyzed using multivariate logistic regression analysis to investigate the factors related to mechanical complications. RESULTS: Of the 156 patients, 114 were men and 42 were women; the mean age was 60.38 years (range 25-83 years), and the mean follow-up duration of follow-up was 37.56 months (range 24-128 months). Thirty-seven patients (23.7%) experienced mechanical complications, and 6 of them underwent revision surgery. The significant risk factors for mechanical complications were low BMD T-score (-1.36 vs -0.58, p = 0.001), a large number of fused vertebrae (5.08 vs 4.54, p = 0.003), a large preoperative C2-7 sagittal vertical axis (SVA; 32.28 vs 23.24 mm, p = 0.002), and low preoperative C2-7 lordosis (1.85° vs 8.83°, p = 0.001). The clinical outcomes demonstrated overall improvement in both groups; however, the neck visual analog scale, Neck Disability Index, and Japanese Orthopaedic Association scores after surgery were significantly worse in the mechanical complication group compared with the group without mechanical complications. CONCLUSIONS: Low BMD, a large number of fused vertebrae, a large preoperative C2-7 SVA, and low C2-7 lordosis were significant risk factors for mechanical complications after posterior cervical fusion surgery. The results of this study could be valuable for preoperative counseling, medical treatment, or surgical planning when multilevel posterior cervical instrumented fusion surgery is performed.


Assuntos
Cifose , Lordose , Fusão Vertebral , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Lordose/diagnóstico por imagem , Lordose/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Laminectomia/efeitos adversos , Fatores de Risco , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Cifose/cirurgia , Resultado do Tratamento
12.
BMB Rep ; 56(2): 190-195, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36404596

RESUMO

We propose a novel blood biomarker detection method that uses miRNA super-resolution imaging to enable the early diagnosis of Alzheimer's disease (AD). Here, we report a singlemolecule detection method for visualizing disease-specific miRNA in tissue from an AD mice model, and peripheral blood mononuclear cells (PBMCs) from AD patients. Using optimized Magnified Analysis of Proteome (MAPs), we confirmed that five miRNAs contribute to neurodegenerative disease in the brain hippocampi of 5XFAD and wild-type mice. We also assessed PBMCs isolated from the whole blood of AD patients and a healthy control group, and subsequently analyzed those samples using miRNA super-resolution imaging. We detected more miR-200a-3p expression in the cornu ammonis 1 and dentate gyrus regions of 3 month-old 5XFAD mice than in wild-type mice. Additionally, miRNA super-resolution imaging of blood provides AD diagnosis platform for studying miRNA regulation inside cells at the single molecule level. Our results present a potential liquid biopsy method that could improve the diagnosis of early stage AD and other diseases. [BMB Reports 2023; 56(3): 190-195].


Assuntos
Doença de Alzheimer , MicroRNAs , Doenças Neurodegenerativas , Camundongos , Animais , MicroRNAs/genética , MicroRNAs/metabolismo , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/genética , Doenças Neurodegenerativas/metabolismo , Leucócitos Mononucleares/metabolismo , Hipocampo/diagnóstico por imagem , Hipocampo/metabolismo
13.
J Korean Neurosurg Soc ; 66(1): 44-52, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36050868

RESUMO

OBJECTIVE: This study aimed to investigate the efficacy of transverse process (TP) hook system at the upper instrumented vertebra (UIV) for preventing screw pullout in adult spinal deformity surgery using the pedicle Hounsfield unit (HU) stratification based on K-means clustering. METHODS: We retrospectively reviewed 74 patients who underwent deformity correction surgery between 2011 and 2020 and were followed up for >12 months. Pre- and post-operative data were used to determine the incidence of screw pullout, UIV TP hook implementation, vertebral body HU, pedicle HU, and patient outcomes. Data was then statistically analyzed for assessment of efficacy and risk prediction using stratified HU at UIV level alongside the effect of the TP hook system. RESULTS: The screw pullout rate was 36.4% (27/74). Perioperative radiographic parameters were not significantly different between the pullout and non-pullout groups. The vertebral body HU and pedicle HU were significantly lower in the pullout group. K-means clustering stratified the vertebral body HU ≥205.3, <137.2, and pedicle HU ≥243.43, <156.03. The pullout rate significantly decreases in patients receiving the hook system when the pedicle HU was from ≥156.03 to < 243.43 (p<0.05), but the difference was not statistically significant in the vertebra HU stratified groups and when pedicle HU was ≥243.43 or <156.03. The postoperative clinical outcomes improved significantly with the implementation of the hook system. CONCLUSION: The UIV hook provides better clinical outcomes and can be considered a preventative strategy for screw-pullout in the certain pedicle HU range.

14.
World Neurosurg ; 168: 349-358, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36527214

RESUMO

OBJECTIVE: Unilateral biportal endoscopic (UBE) spine surgery for spinal diseases has been increasing in popularity because of its favorable outcomes. The goal of this systemic review is to analyze the status of outcomes and complications in lumbar disc herniation during UBE discectomy. METHODS: A comprehensive search of the PubMed, Embase, Web of Science, and OVID databases published until June 30, 2021, was performed. The outcomes of interest were indications, operative time, blood loss, hospital stay, complications, visual analog scale score, and Oswestry Disability Index. RESULTS: Seven studies were included in our research. UBE surgery for lumbar stenosis was excluded. A total of 230 patients with lumbar disc herniation were enrolled in the 7 selected studies. The mean operative time was 74.4 minutes, and the mean length of hospital stay was 4.5 days. Mean incidence of complications reported in the 7 articles was 6.2%. UBE showed shorter hospital stays than did microdiscectomy, no significant differences of Oswestry Disability Index or visual analog scale scores, and good recovery rate among other discectomy techniques (microdiscectomy, full endoscopic transforaminal endoscopic lumbar discectomy, and interlaminar endoscopic lumbar discectomy) at 1 month follow-up. CONCLUSIONS: Even with the small number of studies and reports analyzed, biases were the main limitation of this analysis; overall, the clinical outcomes and complication rates associated with UBE discectomy were relatively good. It is clear that UBE discectomy is a good treatment choice for lumbar disc herniation, but to prevent unique UBE surgery complications, a clear understanding of the surgical procedures and careful efforts to overcome the learning curve are necessary.


Assuntos
Discotomia Percutânea , Deslocamento do Disco Intervertebral , Doenças da Coluna Vertebral , Humanos , Discotomia/métodos , Discotomia Percutânea/métodos , Endoscopia/métodos , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Região Lombossacral/cirurgia , Estudos Retrospectivos , Doenças da Coluna Vertebral/cirurgia , Resultado do Tratamento
15.
Yonsei Med J ; 63(11): 1027-1034, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36303311

RESUMO

PURPOSE: The biplanar whole body imaging system (EOS) is a new tool for measuring the whole body sagittal alignment in a limited space. This tool may affect the sagittal balance of patients compared to conventional whole spine X-ray (WSX). This study aimed to investigate the difference in sagittal alignment between WSX and EOS. MATERIALS AND METHODS: We compared the spinal and pelvic sagittal parameters in 80 patients who underwent EOS and WSX within one month between July 2018 and September 2019. The patients were divided based on sagittally balanced and imbalanced groups according to pelvic tilt (PT) >20°, pelvic incidence-lumbar lordosis >10°, C7-sagittal vertical axis (SVA) >50 mm in WSX. RESULTS: In the sagittally imbalanced group, compared to WSX, the pelvic parameters demonstrated compensation in EOS with smaller PT (27.4±11.6° vs. 24.9±10.9°, p=0.003) and greater sacral slope (SS), and the patients tended to stand more upright with smaller C7-SVA (58.4±17.0 mm vs. 48.9±57.3 mm, p=0.018), T1-pelvic angle (TPA), T5-T12, and T2-T12. However, in the sagittally balanced group, these differences were less pronounced only with smaller PT (10.8±6.9° vs. 9.4±4.7°, p=0.040), TPA and T2-T12 angle, but with similar SS and C7-SVA (p>0.05). CONCLUSION: EOS showed a negative SVA shift and lesser PT compared to WSX, especially in patients with sagittal imbalance. When preparing a surgical plan, surgeons should consider these differences between EOS and WSX.


Assuntos
Cifose , Lordose , Humanos , Cifose/diagnóstico por imagem , Cifose/cirurgia , Raios X , Coluna Vertebral/diagnóstico por imagem , Lordose/diagnóstico por imagem , Radiografia , Sacro , Vértebras Lombares
16.
Neurospine ; 19(3): 524-532, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36203279

RESUMO

OBJECTIVE: Three-dimensional (3D)-printed titanium implants have been developed recently, but the utility is not yet proven. The aim of this study was to compare 3D-printed titanium and polyetheretherketone (PEEK) implants after minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF). METHODS: Between October 2018 and September 2021, we retrospectively analyzed 83 patients who underwent single-level MIS-TLIF (3D-printed titanium, 40; PEEK, 43). Radiologic parameters were assessed with x-ray and computed tomography (CT) at postoperative 1 week, 6 months, and 1 year. Clinical status was evaluated using Oswestry Disability Index, visual analogue scale score, and Bridwell fusion grading was assessed on 6-month and 1-year postoperative CT. RESULTS: There were no differences between the 2 groups in demographics and clinical outcomes. At 1-year of follow-up, the reported 3D-printed titanium fusion grades were grade I: 77.5% (31 patients), grade II: 17.5% (7 patients), and grade III: 5% (2 patients). The PEEK fusion grades were grade I: 51.2% (22 patients), grade II: 41.9% (18 patients), and grade III: 7.0% (3 patients). For overall fusion rate (grade I + II), there was no difference between the 2 cages (95.0% vs. 93.0%, p = 0.705), but grade I was reported at a higher incidence in 3D-printed titanium than PEEK (77.5% vs. 51.2%, p = 0.013). There was no difference between cages based on subsidence and complications. CONCLUSION: There were no significant differences in the overall fusion rate for MIS-TLIF surgery between 3D-printed titanium and PEEK, but the fusion grade was better in 3D-printed titanium than in PEEK. Long-term follow-up is required to verify the effectiveness.

17.
Acta Neurochir (Wien) ; 164(12): 3173-3180, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36251069

RESUMO

STUDY DESIGN: This is a retrospective study. OBJECTIVE: Implant nonfusion is an important prognostic factor for patients after anterior cervical discectomy and fusion (ACDF). This study aimed to investigate endplate-specific pseudarthrosis after ACDF, to determine if the rate of fusion is inferior in the lower endplate, and to identify any differences in clinical and radiological results. Research comparing each endplate on which the endplate affects nonfusion is limited. METHODS: We analyzed 71 patients with 142 total spinal levels who underwent double-level ACDF (C4-5-6 and C5-6-7) with an allograft and plate at our hospital between January 2012 and December 2018. Fusion grades were assessed using computed tomography and the Bridwell fusion grade system at 1 year postoperatively. Radiological parameters were obtained from lateral cervical radiographs collected preoperatively and at 1 month and 1 year after surgery. RESULTS: There was no difference in fusion between the C4-5-6 and C5-6-7 ACDF procedures, but the fusion rate and Bridwell fusion grade at the caudal surgery level were lower than those at the cranial surgery level (93 vs. 79%, p < 0.001). The lower endplate of the caudal fusion level showed the most common pseudarthrosis (18 of 71 [25%]). There was no difference in radiological parameters and clinical outcomes between the fusion and pseudarthrosis groups. CONCLUSION: In double-level ACDF procedures, the nonfusion rate was higher at the caudal fusion levels, especially at the lower endplates of the caudal fusion levels.


Assuntos
Pseudoartrose , Fusão Vertebral , Humanos , Pseudoartrose/diagnóstico por imagem , Pseudoartrose/etiologia , Pseudoartrose/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Fusão Vertebral/métodos , Estudos Retrospectivos , Resultado do Tratamento , Discotomia/métodos
18.
Yonsei Med J ; 63(7): 665-674, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35748078

RESUMO

PURPOSE: This study was undertaken to identify factors that affect segmental lordosis (SL) after minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) by comparing patients whose postoperative SL increased with those whose decreased. MATERIALS AND METHODS: Fifty-five patients underwent MIS-TLIF at our institute from January 2018 to September 2019. Demographic, pre- and postoperative radiologic, and cage-related factors were included. Statistical analyses were designed to compare patients whose SL increased with decreased after surgery. RESULTS: After surgery, SL increased in 34 patients (group I) and decreased in 21 patients (group D). The index level, disc lordosis, SL, lumbar lordosis, proximal lordosis (PL), and Y-axis position of the cage (Yc) differed significantly between groups I and D. The cage in group I was more anterior than that in group D (Yc: 55.84% vs. 51.24%). Multivariate analysis showed that SL decreased more significantly after MIS-TLIF when the index level was L3/4 rather than L4/5 [odds ratio (OR): 0.46, p=0.019], as preoperative SL (OR: 0.82, p=0.037) or PL (OR: 0.68, p=0.028) increased, and as the cage became more posterior (OR: 1.10, p=0.032). CONCLUSION: Changes in SL after MIS-TLIF appear to be associated with preoperative SL and PL, index level, and Yc. An index level at L4/5 instead of L3/4, smaller preoperative SL or PL, and an anterior position of the cage are likely to result in increased SL after MIS-TLIF.


Assuntos
Lordose , Fusão Vertebral , Humanos , Lordose/diagnóstico por imagem , Lordose/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Resultado do Tratamento
19.
Oper Neurosurg (Hagerstown) ; 22(4): 231-238, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35147593

RESUMO

BACKGROUND: The lack of stereoscopic vision in endoscopic spine surgery may lead to a risk of neural or vascular injury during endoscopic surgery. Three-dimensional (3D) endoscopy has not yet been attempted in the field of spinal endoscopic surgery. OBJECTIVE: To present the technique, clinical efficacy, and safety of the 3D biportal endoscopic approach for the treatment of lumbar degenerative disease. METHODS: We attempted 3D biportal endoscopic surgery for lumbar degenerative disease in a series of patients. Clinical outcomes and complications were evaluated postoperatively using a short questionnaire about 3D biportal endoscopic spine surgery that solicited respondents' opinions on the advantages and disadvantages of 3D biportal endoscopic surgery compared to the conventional 2D biportal endoscopic approach. RESULTS: We performed 3D biportal endoscopic spine surgery in 38 patients with lumbar degenerative disease. Optimal neural decompression was revealed by postoperative magnetic resonance imaging in all enrolled patients. The 3D endoscopic vision clearly demonstrated the surgical anatomy starting with the exposure of ligamentum flavum, dura, and nerve root, and 3D endoscopy precisely depicted pathologic lesions such as bony osteophytes and ruptured disc herniation. There were no major complications including neural injury or durotomy. CONCLUSION: The 3D endoscope may be able to distinguish between normal structures and lesions. The stereognosis and depth sensation of 3D biportal endoscopic spinal surgery might have a favorable impact on the safety of patients during endoscopic spine surgery.


Assuntos
Deslocamento do Disco Intervertebral , Estenose Espinal , Descompressão Cirúrgica/métodos , Endoscopia/métodos , Humanos , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/cirurgia
20.
Spine (Phila Pa 1976) ; 47(10): 720-729, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35019880

RESUMO

STUDY DESIGN: Experimental study. OBJECTIVE: In this study, the ambient temperature of a radiofrequency (RF) electrode tip was compared and analyzed in terms of products, mode, flow quantity, and flow rate. SUMMARY OF BACKGROUND DATA: Endoscopic spine surgery is a widely used operation for degenerative lumbar stenosis and herniated lumbar disc. To perform endoscopic spine surgery, dedicated instruments like a RF generator and electrode are essential. METHODS: An evaluation system capable of measuring temperature under equal conditions at a certain distance from the electrode tip was manufactured. The distance between the electrode tip and the temperature sensor was set to 1, 5, and 10 mm. The flow quantities of 0, 50, 100, and 150 mL/min and the flow rates of 0, 0.20, 0.53, and 0.80 m/s were compared and statistically analyzed. RESULTS: The temperatures measured in the experiments conducted on the four combinations of RF device showed similar values, and showed differences according to the characteristics of each mode of the RF. As the distance between the electrode tip and the temperature sensor increased, the temperature decreased, and as flow quantity or flow rate increased, the temperature decreased. The maximum temperatures differed significantly according to flow quantity, between flow quantities of 0 and 100 mL/min (P  = 0.03) and between 0 and 150 mL/min (P ≤ 0.01). The maximum temperatures also differed significantly between the flow rate of 0 m/s, and the flow rates of 0.20, 0.53, and 0.80 m/s, with P ≤ 0.01 in all three comparisons. CONCLUSION: This is the first study in which we made a customized RF temperature evaluation system and verified the temperature changes in various environments. When irrigation was performed, we could confirm that the maximum temperature was less than 60°C. Irrigation is considered essential in endoscopic spine surgery. LEVEL OF EVIDENCE: 3.


Assuntos
Ablação por Cateter , Temperatura Corporal , Eletrodos , Humanos , Modelos Teóricos , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...